← All projects 22 September 2026 Manufacturing · Applied research

Finding mould hot spots and redesigning the cooling channels

Finding mould hot spots and redesigning the cooling channels

Cooling takes 50 to 70 per cent of an injection-moulding cycle and decides both part quality and cycle time. The cavity temperature depends on the cooling channels, but those are usually laid out at even spacing regardless of where the mould actually runs hot. Where cooling falls short, warpage, sink marks, voids and burn marks keep showing up in trials.

Moulders have had no measuring tool between seeing that a mould overheats and knowing which channel to change. Hot zones are read off thermal images by eye, channels are changed on experience, and each change is checked by another trial that takes days. Our research partner surveyed more than 20 moulders, who described lost orders, compensation paid to a carmaker and line stoppages, each running into the millions.

Four steps

  • Find the hot spots: box the area of interest and detect by white threshold, colour or brightness, with each hot spot given a boundary.
  • Line the image up with the drawing: four circular datums give matched point pairs, and the thermal image is projected onto the CAD drawing to check the fit.
  • Map onto the drawing: every hot spot lands at its drawing coordinates, numbered to match the thermal image.
  • Lay out denser channels where needed: tight pitch where the mould runs hot and wider elsewhere, as a zigzag with rounded turns, inlet and outlet.

Three hard problems

  • Matching a thermal image to CAD: one is pixels with perspective distortion, the other is vectors. Matched point pairs on four datums do the alignment, with automatic matching for the first pass.
  • Recognising channels: channels are usually drawn as dashed lines, and tracing them from pixels breaks lines and invents false ones, so the tool reads the .dxf entities directly and picks channels by line type and layer.
  • Staying aligned when zooming and rotating: screen and drawing coordinates are kept separate, so annotations do not drift.

Results on a real mould

On our research partner’s runs against a real mould, the tool mapped all 17 hot spots, recognised 112 existing channels in one pass, and reported zero-pixel alignment error on its four datum pairs. Everything goes into one self-contained HTML report, with the detection mode, thresholds and alignment error at the top and each hot spot listed with its thermal and drawing coordinates, so results can be checked against the originals and filed.

Who did what

Our research partner developed the desktop tool. Orainic built the live web version on the Ingendia demo platform and added a simplified steady-state temperature comparison: on the same plate with the same hot spots, the denser layout lowers the peak temperature rise by 56 per cent compared with even spacing. That comparison shows which way a hot-spot-led layout points; it is an estimate, and it does not replace mould-flow analysis or a trial.

Try the live analysis bench ↗

Next project

AI colour matching for masterbatch, and a nationwide dosing-machine monitoring centre

Starting a project? Let’s connect.

Tell us what you’re building. You’ll get a reply — and a quote with free design feedback — within hours.